Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Nuclear Medicine and Molecular Imaging ; : 275-284, 2008.
Article in Korean | WPRIM | ID: wpr-182739

ABSTRACT

PURPOSE: We intended to evaluate myocardial oxygen consumption (MVO2) by applying recirculation correction and modified one-compartment model to have a reference range of MVO2 in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and METHODS: In nine normal male volunteers with mean age of 26.3+/-4.0, MVO2 was estimated with 925 MBq (25mCi) of 11C-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as MATLAB(R) v7.1 (Mathworks, Inc., United States), Excel(R) 2007 (Microsoft, United States), and SPSS(R) v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of 12 x 10, 5 x 60, 3 x 120, 2 x 300's duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. RESULTS: The normal reference ranges of MVO2 were presented as 3.18-4.64 x 10(-4) ml/g/sec, 1.91-3.94 x 10(-4) ml/g/sec, 4.31-6.40 x 10(-4) ml/g/sec, 2.84-4.53 x 10(-4) ml/g/sec and 3.42-5.00 x 10(-4) ml/g/sec in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. CONCLUSION: 11C-Acetate is a radiotracer worthwhile to assess MVO2. Re-circulated 11C can influence TAC of 11C in myocadia and so the recirculation correction must be considered when measuring MVO2.


Subject(s)
Humans , Male , Academies and Institutes , Acetates , Carbon , Oxygen , Oxygen Consumption , Positron-Emission Tomography , Reference Values
2.
Nuclear Medicine and Molecular Imaging ; : 327-331, 2006.
Article in Korean | WPRIM | ID: wpr-224477

ABSTRACT

PURPOSE: Aspiration scintigraphy is a procedure of nuclear imaging to evaluate aspiration and of quantifying the amount of aspirate. The ultimate goal of our study is to define the correlation between aspiration and aspiration pneumonia by aspiration scintigraphy, and this is a preliminary report of its trial. MATERIALS AND METHODS: Ten patients with positive findings by videofluoroscopy were selected. The patients ingested semi-solid food containing Tc-99m tin colloid 92.5 MBq (2.5 mCi) and images were acquired immediately after the ingestion and 3 hrs later. A fraction of aspiration to the ingested was calculated using an equation with a decay correction. RESULTS: Five patients were interpreted positive by aspiration scintigraphy. Four patients were positive at initial images and the fractions of aspiration were 0.11%, 0.11%, 0.81%, and 0.11%. The one patient who was shown aspirated at both images had initial 5.82% and delayed 2.26%. CONCLUSION: Aspiration scintigraphy enables us to localize the aspiration at any desired time of the test and to quantify its amount. Follow-up studies are warranted.


Subject(s)
Humans , Colloids , Eating , Pneumonia, Aspiration , Radionuclide Imaging , Tin
3.
Nuclear Medicine and Molecular Imaging ; : 190-191, 2006.
Article in Korean | WPRIM | ID: wpr-48943

ABSTRACT

A 44-year-old man with a past medical history of splenectomy came to hospital because of epigastric pain. Abdominopelvic computed tomography(CT) showed a soft tissue mass and multifocal variable-sized nodules as well as findings suggestive of cholecystitis. Subsequently, he underwent Tc-99m-labeled heat-denatured red blood cell(RBC) scintigraphy to evaluate the mass and nodules. The scintigraphy confirmed multifocal peritoneal splenosis in the abdominopelvic cavity.


Subject(s)
Adult , Humans , Cholecystitis , Erythrocytes , Radionuclide Imaging , Spleen , Splenectomy , Splenosis
4.
Korean Journal of Nuclear Medicine ; : 257-262, 2005.
Article in Korean | WPRIM | ID: wpr-115915

ABSTRACT

PURPOSE: Gastric emptying scan (GES) is usually acquired up to 2 hours. Our study investigated whether a fraction of meal-retention in the stomach at 120 minutes (FR120) was predicted from the data measured for 90 minutes by using non-linear curve fitting. We aimed at saving the delayed imaging by utilizing mathematical models. MATERIALS AND METHODS: Ninety-six patients underwent GES immediately after taking a boiled egg with 74 MBq (2 mCi) Tc-99m DTPA. The patients were divided into Group I (T1/2 < or=90 min) and Group II (90 min< T1/2< or=120 min). Group I (n=51) had 21 men and 30 women, and Group II (n=45) 15 men and 30 women. There was no significant difference in age and sex between the two groups. Simple exponential, power exponential, and modified power exponential curves were acquired from the measured fraction of meal-retention at each time (0, 15, 30, 45, 60, 75, and 90 min) by non-linear curve fitting (MATLAB (R) 5.3) and another simple exponential fitting was performed on the fractions at late times (60, 75, and 90 min). A predicted FR120 was calculated from the acquired functional formulas. A correlation coefficient between the measured FR120 and the predicted FR120 was computed (MedCalc (R) 6.0). RESULTS: Correlation coefficients (r) between the measured FR120 and the predicted FR120 of each mathematical functions were as follows: simple exponential function (Group I: 0.8858, Group II: 0.5982, p< 0.0001), power exponential function (Group I: 0.8755, Group II: 0.6008, p< 0.0001), modified power exponential function (Group I: 0.8892, Group II: 0.5882, p< 0.0001), and simple exponential function at the late times (Group I: 0.9085, Group II: 0.6832, p< 0.0001). In all the fitting models, the predicted FR120 were significantly correlated with the measured FR120 in Group I but not in Group II. There was no statistically significant difference in correlation among the 4 mathematical models. CONCLUSION: In the cases with T1/2 < or=90 min, the predicted FR120 is significantly correlated with the measured FR120. Therefore, FR120 can be predicted from the data measured for 90 minutes by using non-linear curve fitting, saving the delayed imaging after 90 minutes when T1/2 < or=90 min is ascertained.


Subject(s)
Female , Humans , Male , Gastric Emptying , Models, Theoretical , Ovum , Pentetic Acid , Radionuclide Imaging , Stomach
5.
Korean Journal of Nuclear Medicine ; : 209-211, 2005.
Article in Korean | WPRIM | ID: wpr-106854

ABSTRACT

A tail-on-detector (TOD) view has been used to see the symphysis pubis or sacrococcyx in skeletal scintigraphy, but it is inconvenient to acquire because a patient must sit or lean on a detector. The TOD views are still frequently performed in training hospitals in Korea, although it is becoming almost impossible to sit on a camera in this age of dual-headed cameras. The authors show cases with lateral views obtained in supine position that were acquired for the same reason; they are easier and more useful than the TOD views.


Subject(s)
Humans , Coccyx , Korea , Radionuclide Imaging , Sacrococcygeal Region , Sacrum , Supine Position , Technetium Tc 99m Medronate
SELECTION OF CITATIONS
SEARCH DETAIL